We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

PURPOSE: To demonstrate feasibility of monitoring high-intensity focused ultrasound (HIFU) treatment with passive acoustic mapping of broadband and harmonic emissions reconstructed from filtered-channel radiofrequency data in ex vivo bovine tissue. MATERIALS AND METHODS: Both passive acoustic emissions and B-mode images were recorded with a diagnostic ultrasound machine during 180 HIFU exposures of five freshly excised, degassed bovine livers. Tissue was exposed to peak rarefactional pressures between 3.6 and 8.0 MPa for 2, 5, or 10 seconds. The B-mode images were analyzed for hyperechoic activity, and threshold levels were determined for the harmonic (1.17 mJ) and broadband (0.0137 mJ) components of the passively reconstructed source energy to predict tissue ablation. Both imaging methods were compared with tissue lesions after exposure to determine their spatial accuracy and their capability to help predict presence of ablated tissue. Performance of both methods as detectors was compared (matched-pair test design). RESULTS: Passive mapping successfully aided prediction of the presence of tissue ablation more often than did conventional hyperechoic images (49 of 58 [84%] vs 31 of 58 [53%], P < .001). At 5.4-6.3-MPa exposures, sensitivity, specificity, negative predictive value, and positive predictive value of the two methods, respectively, were 15 of 20 versus five of 21 (P = .006), eight of nine versus eight of nine (P = .72), 15 of 16 versus five of six (P = .53), and eight of 13 versus eight of 24 (P = .011). Across HIFU exposure amplitude ranges, passive acoustic mapping also aided correct prediction of the visually detected location of ablation following tissue sectioning in 42 of 45 exposures for which the harmonic and broadband threshold levels for tissue ablation were exceeded. Early cavitation activity indicated the focal position within the tissue before irreversible tissue damage occurred. CONCLUSION: Passive acoustic mapping significantly outperformed the conventional hyperecho technique as an ultrasound-based HIFU monitoring method, as both a detector of lesion occurrence and a method of mapping the position of ablated tissue.

Original publication

DOI

10.1148/radiol.11110670

Type

Journal article

Journal

Radiology

Publication Date

01/2012

Volume

262

Pages

252 - 261

Keywords

Acoustics, Animals, Cattle, Feasibility Studies, High-Intensity Focused Ultrasound Ablation, Image Processing, Computer-Assisted, In Vitro Techniques, Liver, Sensitivity and Specificity, Transducers