We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Background. Obtaining intra-operative watertight closure of the dura is considered important in reducing post-operative cerebrospinal fluid (CSF) leak. The purpose of this study was to evaluate a fibrin sealant as an adjunct to sutured dural repair to obtain intra-operative watertight closure in cranial neurosurgery. Methods. This randomized, controlled multicenter study compared a fibrin sealant (EVICEL® Fibrin Sealant [Human]) to sutured dural closure (Control). Subjects underwent supratentorial or posterior fossa procedures. Following primary dural repair by sutures, the closure was evaluated for intra-operative CSF leak by moderately increasing the intracranial pressure. If present, subjects were randomized to EVICEL® or additional sutures (2:1 ratio), stratified by surgical approach. Following treatment, subjects were successful if no CSF leaks were present during provocative challenge. Safety was assessed to 30 days post-surgery, including incidence of CSF leakage. Results. One hundred and thirty-nine subjects were randomized: 89 to EVICEL® and 50 to Control. Intra-operative watertight closure was achieved in 92.1% EVICEL®-treated subjects versus 38.0% controls; a treatment difference of 54.1% (p < 0.001). The treatment differences in the supratentorial and posterior fossa strata were 49.1% and 75.7%, respectively (p < 0.001). The incidence of adverse events was similar between treatment groups. No deaths or unexpected serious adverse drug reactions were reported. CSF leakage within 30 days post-operatively was 2.2% and 2.0% in EVICEL® and control groups, respectively. In addition, 2 cases of CSF rhinorrhoea were observed in the EVICEL® group. Although not associated with the suture line where EVICEL® was applied, when combined with the other CSF leaks, the observed leak rate in the EVICEL® group was 4.5%. Conclusions. These results indicate that EVICEL® is effective as an adjunct to dural sutures to provide watertight closure of the dura mater in cranial surgery. The study confirmed the safety profile of EVICEL®.

Original publication

DOI

10.3109/02688697.2014.948808

Type

Journal article

Journal

Br J Neurosurg

Publication Date

12/08/2014

Pages

1 - 7

Keywords

cerebrospinal fluid leak, dural repair, fibrin sealant, watertight dural closure