We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

OBJECTIVE: To obtain data on conventional artificial filling cystometry and ambulatory monitoring in healthy asymptomatic control populations. SUBJECTS AND METHODS: Seventeen healthy volunteers were assessed by means of artificial filling cystometry (CMG), filling at rates of 50 ml/min (CMG 50) and 100 ml/min (CMG 100), and ambulatory monitoring (AM). RESULTS: Significant differences were found between AM and CMG with respect to: the pressure rise on filling (P < 0.02), voided volumes (P < 0.01) and maximum detrusor pressure on micturition (P < 0.01). Detrusor instability was found in 38% of volunteers on AM, in 17% on CMG 50, but in none on CMG 100. CONCLUSION: A range of baseline urodynamic values has been established which could provide the basis for future studies of ambulatory monitoring.