We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Elevated cystatin C in blood reflects impaired glomerular filtration rate (GFR), but current cystatin C assays, based on polyclonal antibodies and immunoturbidimetric or nephelometric detection, have several limitations. We evaluated a new immunoassay based on monoclonal antibodies in samples from patients with and without chronic kidney disease (CKD). METHODS: The study enrolled 170 men without known CKD (Group A) and 104 men with CKD (Group B). All patients were assessed with iohexol clearance, plasma creatinine and plasma cystatin C by a conventional particle-enhanced immunoturbidimetric assay (PETIA) and by the new double monoclonal assay. In Group A, three serial blood draws were performed at median intervals of 4 h and 12 days between samples, to also allow assessments of the variability in cystatin C values with the new assay. Concordance correlation coefficients and the 95% limits of agreement were used to estimate the agreement of reciprocal cystatin C and reciprocal creatinine with iohexol clearance. RESULTS: Median iohexol clearance (mL/min/1.73 m(2)) was 81 [interquartile range (IQR) 70, 92] in Group A and 23 (IQR 16, 34) in Group B. The concordance correlation with GFR for the new cystatin C assay compared to the established assay was similar in Group A (0.441 versus 0.465) but higher in Group B (0.680 versus 0.593). Cystatin C measured by both assays exhibited closer agreement with GFR than creatinine. The agreement between the two cystatin C assays was high, with concordance correlations of 0.815 in Group A and 0.935 in Group B. Compared to the conventional assay, the new assay tended to yield lower values of cystatin C at the low end of the range in Group A. The new cystatin C assay exhibited small intraindividual variability across serial samples (coefficient of variation ≤ 6%). CONCLUSIONS: In this first clinical evaluation, the new cystatin C assay performed similarly to the established PETIA in patients with normal GFR and better in patients with CKD. The new assay may offer an alternative to current commercial assays to detect and monitor impaired kidney function.

Original publication

DOI

10.1093/ndt/gfr350

Type

Journal article

Journal

Nephrol Dial Transplant

Publication Date

02/2012

Volume

27

Pages

682 - 687

Keywords

Aged, Antibodies, Monoclonal, Case-Control Studies, Creatinine, Cystatin C, Glomerular Filtration Rate, Humans, Immunoassay, Iohexol, Male, Middle Aged, Reference Values, Renal Insufficiency, Chronic, Reproducibility of Results, Sensitivity and Specificity, Severity of Illness Index