Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: The SentiMAG Multicentre Trial evaluated a new magnetic technique for sentinel lymph node biopsy (SLNB) against the standard (radioisotope and blue dye or radioisotope alone). The magnetic technique does not use radiation and provides both a color change (brown dye) and a handheld probe for node localization. The primary end point of this trial was defined as the proportion of sentinel nodes detected with each technique (identification rate). METHODS: A total of 160 women with breast cancer scheduled for SLNB, who were clinically and radiologically node negative, were recruited from seven centers in the United Kingdom and The Netherlands. SLNB was undertaken after administration of both the magnetic and standard tracers (radioisotope with or without blue dye). RESULTS: A total of 170 SLNB procedures were undertaken on 161 patients, and 1 patient was excluded, leaving 160 patients for further analysis. The identification rate was 95.0 % (152 of 160) with the standard technique and 94.4 % (151 of 160) with the magnetic technique (0.6 % difference; 95 % upper confidence limit 4.4 %; 6.9 % discordance). Of the 22 % (35 of 160) of patients with lymph node involvement, 16 % (25 of 160) had at least 1 macrometastasis, and 6 % (10 of 160) had at least a micrometastasis. Another 2.5 % (4 of 160) had isolated tumor cells. Of 404 lymph nodes removed, 297 (74 %) were true sentinel nodes. The lymph node retrieval rate was 2.5 nodes per patient overall, 1.9 nodes per patient with the standard technique, and 2.0 nodes per patient with the magnetic technique. CONCLUSIONS: The magnetic technique is a feasible technique for SLNB, with an identification rate that is not inferior to the standard technique.

Original publication

DOI

10.1245/s10434-013-3379-6

Type

Journal article

Journal

Ann Surg Oncol

Publication Date

04/2014

Volume

21

Pages

1237 - 1245

Keywords

Adult, Aged, Breast Neoplasms, Carcinoma, Ductal, Breast, Carcinoma, Intraductal, Noninfiltrating, Coloring Agents, False Negative Reactions, Female, Follow-Up Studies, Humans, International Agencies, Lymph Nodes, Magnetic Phenomena, Middle Aged, Neoplasm Grading, Neoplasm Invasiveness, Neoplasm Staging, Prognosis, Sentinel Lymph Node Biopsy