We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: In an era where global kidney shortage has pushed the field of transplantation towards using more marginal donors, modified kidney preservation techniques are currently being reviewed. Some techniques require further optimization before implementation in full scale transplantation studies. Using a porcine donation after circulatory death kidney model, we investigated whether initial kidney hemodynamics improved during normothermic machine perfusion if this was preceded by a short period of oxygenated hypothermic machine perfusion (oxHMP) rather than static cold storage (SCS). METHODS: Kidneys subjected to 75 minutes of warm ischemia were randomly assigned to either SCS (n = 4) or SCS + oxHMP (n = 4), with a total cold storage time of 240 minutes. Cold preservation was followed by 120 minutes of normothermic machine perfusion with continuous measurement of hemodynamic parameters and renal function. RESULTS: oxHMP preserved kidneys maintained significantly lower renal resistance throughout the normothermic machine perfusion period compared to SCS kidneys (P 

Original publication

DOI

10.1097/TXD.0000000000001108

Type

Journal article

Journal

Transplant Direct

Publication Date

02/2021

Volume

7