Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Early graft failure is a common cause of cardiac mortality and morbidity after coronary artery bypass grafting, but there is little information on its natural incidence. Furthermore, there is particular concern about graft patency in off-pump coronary artery bypass grafting and total arterial grafting. METHODS: We performed a prospective observational study to assess intraoperative graft patency in patients undergoing off-pump and on-pump coronary artery bypass grafting, who also underwent total arterial grafting. We used an intraoperative imaging system, SPY (Novadaq Technologies Inc), based on the fluorescent properties of indocyanine green dye. RESULTS: We assessed the intraoperative graft patency of 533 conduits in 200 patients. The mean number of grafts was 2.7 per patient. Of these patients, 155 (78%) had off-pump coronary artery bypass grafting, and 45 (22%) had on-pump coronary artery bypass grafting. Overall, 161 (80%) had total arterial grafting, with composite arterial grafting performed in 120 (60%) patients. Fluorescence, confirming graft patency, was observed in all but 8 (1.5%) conduits in 8 (4%) patients, necessitating graft revision. Six (3.9%) and 2 (4.4%) of these patients, respectively, had off-pump coronary artery bypass grafting and on-pump coronary artery bypass grafting. CONCLUSION: Intraoperative fluorescence imaging demonstrated a low (1.5%) but well-defined incidence of intraoperative graft failure, which affects around 4% of patients. This emphasizes the need for routine assessment of graft patency. Intraoperative fluorescence imaging permits detection and revision of failed grafts in the operating room. We found no difference in the incidence of failed grafts when comparing on-pump and off-pump total arterial grafting.

Original publication

DOI

10.1016/j.jtcvs.2003.11.072

Type

Journal article

Journal

J Thorac Cardiovasc Surg

Publication Date

08/2004

Volume

128

Pages

238 - 244

Keywords

Aged, Female, Humans, Incidence, Internal Mammary-Coronary Artery Anastomosis, Intraoperative Complications, Male, Middle Aged, Prospective Studies, Vascular Patency