We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Accurate islet quantification has proven difficult to standardize in a good manufacturing practices (GMP) approved manner. METHODS: The influence of assessment variables from both manual and computer-assisted digital image analysis (DIA) methods were compared using calibrated, standardized microspheres or islets alone. Additionally, a mixture of microspheres and exocrine tissue was used to evaluate the variability of both the current, internationally recognized, manual method and a novel GMP-friendly purity- and volume-based method (PV) evaluated by DIA in a semiclosed, culture bag system. RESULTS: Computer-assisted DIA recorded known microsphere size distribution and quantities accurately. By using DIA to evaluate islets, the interindividual manually evaluated percent coefficients of variation (CV%; n=14) were reduced by almost half for both islet equivalents (IEs; 31% vs. 17%, P=0.002) and purity (20% vs. 13%, P=0.033). The microsphere pool mixed with exocrine tissue did not differ from expected IE with either method. However, manual IE resulted in a total CV% of 44.3% and a range spanning 258 k IE, whereas PV resulted in CV% of 10.7% and range of 60 k IE. Purity CV% for each method were similar approximating 10.5% and differed from expected by +7% for the manual method and +3% for PV. CONCLUSION: The variability of standard counting methods for islet samples and clinical quantities of microspheres mixed with exocrine tissue were reduced with DIA. They were reduced even further by use of a semiclosed bag system compared with standard manual counting, thereby facilitating the standardization of islet evaluation according to GMP standards.

Original publication

DOI

10.1097/TP.0b013e31820ae48e

Type

Journal article

Journal

Transplantation

Publication Date

27/03/2011

Volume

91

Pages

677 - 683

Keywords

Calibration, Cell Size, Humans, Image Processing, Computer-Assisted, Islets of Langerhans, Islets of Langerhans Transplantation, Microspheres, Reproducibility of Results